UC864-E/G/WD/WDU Hardware User Guide
1vv0300766a Rev.4
- 03/02/09
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 20 of 78
4.3. Turning OFF the UC864-E/G/WD/WDU
Turning off the device can be done in three ways:
• by software command (see UC864-E/G/WD/WDU Software User Guide)
• by hardware shutdown
• by Hardware Unconditional Restart
When the device is shut down by software command or by hardware shutdown, it
issues to the network a detach request that informs the network that the device will
not be reachable any more.
4.3.1. Hardware Shutdown
To turn OFF UC864-E/G/WD/WDU the pad ON# must be tied low for at least 2
seconds and then released. Same circuitry and timing for the power on must be used.
The device shuts down after the release of the ON# pad.
4.3.2. Hardware Unconditional Restart
To unconditionally restart UC864-E/G/WD/WDU, the pad RESET# must be tied low
for at least 200 milliseconds and then released.
A simple circuit to do it is:
NOTE:
To turn OFF UC864-E version, first of all, you MUST cut off the supplying power to
the USB_VBUS, or the module does not turn off.
TIP:
To check if the device has powered off, hardware line PWRMON must be monitored.
When PWRMON goes low, the device has powered off.
RESET#
Unconditional Restart
impulse
GND
Comments to this Manuals