DRAiNiNG WATER FOR OpTiONAL DRAiN pUMp AppLiCATiONS
Remove the drain pump from the ice maker (refer to Drain Pump Installation Instructions).A.
Drain the water in the drain pumps reservoir by turning the pump upside down and allowing water to drain through the B.
pumps inlet and vent tube fittings.
After all water is drained, reinstall the drain pump. Make certain all tubing is installed and all hose clamps are tight (refer C.
to Drain Pump Installation Instructions).
TO RESTART ThE iCE MAkER
With the rocker switch in the OFF position, plug the unit into an electrical outlet.A.
Reconnect or turn on the water supply line.B.
Reconnect drain tubing if removed.C.
Turn the rocker switch to the ON position.D.
Check the water inlet, drain lines, and fittings for any water leaks.E.
Check drain pump (if equipped) operation by pouring approximately two (2) quarts of water into the ice storage bin. The F.
drain pump should activate and discharge water (refer to Drain Pump Installation Instructions). Check for water leaks at
all hose connections.