ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS  RGU & RGUC MODELS
The electrical supply must be a correctly polarized 120 volt AC, 60 Hz,
single phase circuit suitable for the maximum current draw of the model,
as detailed in the table below. Please verify your model’s current draw by
checking the rating label on the back of the range.
REQUIRED GROUNDING METHOD  RGU & RGUC
MODELS
This appliance is factory equipped with a power supply cord with a
three-prong grounding plug (with polarized parallel blades). It must be plugged into a mating grounding-type
receptacle, connected to a correctly polarized 120 volt circuit. If the circuit does not have a grounding type
receptacle, it is the responsibility and obligation of the installer to have the existing receptacle changed to a
properly grounded and polarized receptacle in accordance with all applicable local codes and ordinances by
a qualified electrician. In the absence of local codes and ordinances, the receptacle replacement shall be in
accordance with the National Electrical Code.
Note:
The third prong should not, under ANY circumstances, be cut or removed.
Receptacle Box
Cover Plate
Three Prong
Receptacle
Three
Prong
Plug
Fig. 15a Connecting the range to the power supply -
RGU & RGUC Models
BACKGUARD INSTALLATION
The backguard is located as shown in Fig. 14. Secure
the backguard to the range (standard backguards) or
the wall behind the range (full backguards). Specific
instructions for installation can be found packaged
with the backguard. See also “Planning The Instal-
lation” section. A backguard (standard or full) must
be installed when there is less than a 12” clearance
between combustibles and the back of the range
(above the cooking surface). See Fig. 13.
RGU and RGUC models are supplied with a standard
range mount backguard. For RDU models, DCS
backguards are sold separately.
Important!
Always disconnect electric
supply cord from the wall
outlet or service disconnect
before servicing this appliance.
Observe all governing codes and
ordinances when grounding,
in absence of which, observe
National Electrical Code ANSI /
NFPA No. 70.
Fig. 14
26-1/2"
3-1/2"
1-5/16"
11-13/32"
3-1/2"
13/16"
Wall Mount
Full Backguard
(BGRU-3030,
BGRU-3036,
BGRU-3048)
Range Mount
Standard
Backguard
(BGRU2-1530,
BGRU2-1536,
BGRU2-1548)
The rating label is located on the back
of the range
A wiring diagram label is attached to
the back of the range
Wiring diagrams
are also included in
the service
summary, attached
to the inside of the
kick panel
US
CA
MODEL MAX. CURRENT DRAW CIRCUIT TO USE
RGU-305
5 amp 15 amp
RGU-364GD
8 amp 15 amp
RGU-364GL
8 amp 15 amp
RGU-366
5 amp 15 amp
RGU-484GG
15 amp 15 amp
RGU-485GD
15 amp 15 amp
RGU-486GD
12 amp 15 amp
RGU-486GL
12 amp 15 amp
RGUC-305
5 amp 15 amp