COOKTOP USE
BURNERS
Your new professional gas range is equipped with
burners typica[ of those used in restaurants. These
burners are designed for maximum cHeanabHity and
controHHabHity. The [arge cap spreads the simmer heat out
to avoid too much heat being concentrated on the center
of the pan. The simmer flame is aHways on when the
burner is in use.The burner shouHd never be operated if
the cap is not in pHace. AH[ the cooktop burners have
eHectronic spark ignition to eHiminate continuousHy
burning pilots; when the burner is on and the flame is
bHown out, it wH[ reHight.
Port
Ring
Cap
Simmer
FHame
Fig. 1
SIMMERING
Your new professionaH cooktop has exceptionaHHy How
simmering capabiHities, The Harge cap serves as a heat
diffuser to spread out the heat to avoid having a center
hotspot, Keep in mind that because of the high heat
capacity of the outer burner, and the mass of the cast iron
burner grates (they retain heat Monger than Highter,
conventionaH grates) some foods may continue to cook
by retained heat after the burner has been turned off,
ShouHd a strong draft or boiH over extinguish the simmer
flame it wiHHreHight automaticaHHy as the main burner
€_12; .......
RGS-305 COOKTOP SECTHONSHOWN
wouHd.
ELECTRONIC IGNITERS
ff a burner does not ignite,
Histen for the cHicking sound,
ff the igniter is not cHicking,
TURN OFF THE BURNER,
Check the circuit breaker for
a bHown fuse or a tripped
circuit breaker, Hfthe igniter
stiHHfaiHsto operate, see
Burner Max.
Location 8tu/hr
305 Nat 36"/48" Nat* LP Nat LP
1 16,000 17,500 14,000 500-1,200 500-1,200
2 16,000 17,500 14,000 500-1,200 500-1,200
3 17,500 17,500 _* 14,000 500-1,200 500-1,200
4 16,000 17,500 14,000 500-1,200 500-1,200
5 16,000 17,500 14,000 500-1,200 500-1,200
Note- M[burners on 36 & 48 modems (except 485 modems) rated at 117,500 Btu/hr for Nat. &l 4,000Btu/hr for LR
/
[__485 modem onHy.No Hocation #3 on 36 & other 48 modems.
page 30,"Before Ca[ling For
Service" To light the burner
manually, see page 27
"Power Failure':
NOTE: If you are using propene gas, a slight pop or flash
may occur at the bumer ports a few seconds after
the burner has been turned "off': This "extinction
pop" is normal for propane gas.
Hgniter (Keep Clean)
@